Boiler & Cooling Chemical Programs
Six categories of specialty treatment — each with verified specifications from Lenntech's official datasheets.
OptiSperse HP Series
- Type: Liquid phosphate + polymer dispersant
- Function: Metal oxide deposit & caustic corrosion control
- Application: Steam boilers fed with demin water & condensate
- Polymer: Synthetic carboxylated polymer for iron dispersion
- Compatible: FDA-regulated systems
- Dosing: Direct to boiler feed line or boiler
Belclene 810 Biodegradable
- Type: Biodegradable antiscalant
- Application: Severe high-LSI cooling water systems
- Function: Threshold inhibition + crystal modification
- Targets: CaCO₃, CaSO₄, BaSO₄, SrSO₄
- pH range: < 2
- Appearance: Amber liquid
Oxygen Scavengers
- Function: Remove dissolved oxygen from boiler feedwater
- Chemistry: Hydrazine, carbohydrazide, DEHA, erythorbate
- Application: Steam boilers, closed loops
- Benefit: Prevents pitting corrosion in boiler tubes
- Dosing: Proportional to feedwater flow & O₂ level
- Monitoring: DULCOTEST oxygen sensors
Scale Inhibitors
- Type: Phosphonate, polycarboxylate, polymer blends
- Targets: CaCO₃, CaSO₄, Ca₃(PO₄)₂, silica, iron
- Application: Boiler feedwater, cooling towers
- NSF certified: For potable water systems
- Dosing: 2–10 mg/L (typical)
- Monitoring: DULCOMETER controllers
Corrosion Inhibitors
- Type: Filming amines, neutralizing amines, molybdates
- Function: Protect condensate return lines & boiler tubes
- Application: Steam boilers, closed cooling loops
- pH control: Neutralizing amines raise condensate pH
- Filming: Amine film protects metal surfaces
- Monitoring: Coupon racks, real-time corrosion monitors
Cooling Tower Chemicals
- Scale control: Belclene 810, OptiSperse HP
- Corrosion control: Molybdate, zinc, phosphonate blends
- Biocides: Bellacide 355, LiquiBrom 4600
- Dispersants: Polymer-based for suspended solids
- pH control: Sulfuric acid or caustic dosing
- Monitoring: DULCOMETER, coupon racks
Compare Treatment Programs
All specifications below are taken directly from Lenntech's official datasheets.
| Parameter | OptiSperse HP | Belclene 810 | Oxygen Scavengers | Scale Inhibitors | Corrosion Inhibitors | Cooling Tower Chemicals |
|---|---|---|---|---|---|---|
| Category | Boiler Deposit Control | Biodegradable Antiscalant | Oxygen Removal | Scale Prevention | Corrosion Protection | Cooling Tower Program |
| Brand | SUEZ | BWA | SUEZ / BWA | BWA / SUEZ | SUEZ / BWA | BWA / SUEZ |
| Type | Liquid phosphate + polymer | Biodegradable polymer | Hydrazine, carbohydrazide, DEHA, erythorbate | Phosphonate, polycarboxylate, polymer | Filming amines, neutralizing amines, molybdates | Multi-component program |
| pH Range | Alkaline (boiler water) | < 2 | Boiler feedwater pH | Wide range | Condensate pH control | Cooling water pH range |
| Appearance | Liquid | Amber liquid | Liquid (varies) | Liquid | Liquid | Liquid (multiple products) |
| Dosing | To boiler feed line or boiler | Cooling water systems | Proportional to feedwater flow | 2–10 mg/L (typical) | To condensate return lines | Multiple dosing points |
| Application | Steam boilers (demin water) | High-LSI cooling water | Steam boilers, closed loops | Boiler feedwater, cooling towers | Steam boilers, closed cooling loops | Open recirculating cooling towers |
| Certification | FDA-regulated compatible | Biodegradable | — | NSF certified (some) | — | NSF certified (some) |
| Monitoring | Phosphate reserve & pH | LSI / SDSI monitoring | O₂ sensors, DULCOTEST | DULCOMETER controllers | Coupon racks, real-time monitors | DULCOMETER, coupon racks |
| Benefit | Reduces maintenance costs, protects against metal oxide deposits | Environmentally preferred chemistry | Prevents pitting corrosion | Prevents scale deposits & efficiency loss | Extends equipment life | Complete protection program |
When to Use What
Three common scenarios — and the chemical program that solves them.
Scale Formation in Boilers
Use OptiSperse HP to control metal oxide deposits and caustic corrosion in steam boilers fed with demin water and condensate. For cooling water scale, use Belclene 810 (biodegradable) or phosphonate-based Scale Inhibitors.
Oxygen Corrosion
Use Oxygen Scavengers (hydrazine, carbohydrazide, DEHA, or erythorbate) to remove dissolved oxygen from boiler feedwater. This prevents pitting corrosion in boiler tubes and extends equipment life.
Cooling System Protection
Use Cooling Tower Chemicals — a complete program combining Belclene 810 (scale), Corrosion Inhibitors (molybdate/zinc blends), and Bellacide 355 (biocide) to protect open recirculating cooling systems.
How Chemical Programs Protect Boilers & Cooling Systems
Watch how industrial water treatment systems integrate chemical dosing, reverse osmosis, and membrane separation to protect boilers and cooling towers. This 3D animation shows the full process — including the chemical conditioning and dosing stages that TOP Technique supports every day.
Request Chemical Program →Need a Boiler or Cooling Water Treatment Program?
Send us your water analysis, boiler pressure, and cooling system details — our engineers will recommend the optimal chemical program and provide a full quotation.